TY - JOUR
T1 - Un-steady state modeling for free cyanide removal and biofilm growth in a RBC batch process
AU - Burneo, Belén Sotomayor
AU - Juárez, A. Sánchez
AU - Nieto-Monteros, Diego Alejandro
N1 - Publisher Copyright:
© 2019 Elsevier B.V.
PY - 2020/4/15
Y1 - 2020/4/15
N2 - Biofilm growth and free cyanide biological removal from gold mine wastewater were modeled and simulated using a bench-scale rotating biological contactor (RBC). Eight batch cultures were run in three independent compartments (1.7 L, each) of the RBC. The system worked under the following conditions: [CNi-] = 0.3 g/L, pH = 10.5 ± 0.5, T = 20 ± 5 °C, ω =5 rpm, and 40.5 % of disc submersion. During each culture, biofilm thickness, biomass, and free cyanide concentration in the liquid were quantified. Subsequently, μmax, KCN-,Y'X/CN-, qmax, b', Df, k, and JCN- were determined using experimental data to later model and simulate the biofilm thickness and free cyanide biological removal with Wolfram Mathematica software. After the experiments, free cyanide biological removal was 96.33 % after three days, and maximum biofilm thickness was 0.0292 cm in the 16th day. Moreover, biofilm growth and free cyanide consumption models were adjusted to the experimental data with r2 = 0.90 and r2 = 0.99. Also, there was an equivalent error of 7.89 and 7.38 and a standard deviation of 10.89 % and 10.17 %, between the models and their experimental data, respectively. Finally, the proposed models will allow improvement of reactor operation and its design.
AB - Biofilm growth and free cyanide biological removal from gold mine wastewater were modeled and simulated using a bench-scale rotating biological contactor (RBC). Eight batch cultures were run in three independent compartments (1.7 L, each) of the RBC. The system worked under the following conditions: [CNi-] = 0.3 g/L, pH = 10.5 ± 0.5, T = 20 ± 5 °C, ω =5 rpm, and 40.5 % of disc submersion. During each culture, biofilm thickness, biomass, and free cyanide concentration in the liquid were quantified. Subsequently, μmax, KCN-,Y'X/CN-, qmax, b', Df, k, and JCN- were determined using experimental data to later model and simulate the biofilm thickness and free cyanide biological removal with Wolfram Mathematica software. After the experiments, free cyanide biological removal was 96.33 % after three days, and maximum biofilm thickness was 0.0292 cm in the 16th day. Moreover, biofilm growth and free cyanide consumption models were adjusted to the experimental data with r2 = 0.90 and r2 = 0.99. Also, there was an equivalent error of 7.89 and 7.38 and a standard deviation of 10.89 % and 10.17 %, between the models and their experimental data, respectively. Finally, the proposed models will allow improvement of reactor operation and its design.
KW - Biofilm
KW - Biological removal
KW - Free cyanide
KW - Mathematical model
KW - Rotating biological contactor
UR - http://www.scopus.com/inward/record.url?scp=85078798717&partnerID=8YFLogxK
U2 - 10.1016/j.jhazmat.2019.05.040
DO - 10.1016/j.jhazmat.2019.05.040
M3 - Artículo
C2 - 32029309
AN - SCOPUS:85078798717
SN - 0304-3894
VL - 388
JO - Journal of Hazardous Materials
JF - Journal of Hazardous Materials
M1 - 120647
ER -